453RAC系列Hawke铠装防爆格兰

所在地: 上海市
发布时间: 2024-12-06
详细信息
HAWKE 501/453/RAC CABLE GLANDSHAWKE铠装防爆格兰(501/453/RAC系列)

HAWKE代理商:上海颐品自动化科技有限公司 

Hazardous Area Cable Glands from Hawke

Hawke 501/453/RAC cable glands are suitable for use with single wire armour ‘W’, wire braid ‘X’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.

Hawke 501/453/RAC cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC, 3.2-91.6mm outside cable diameters.

When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

Exdb IIC Gb, Exeb IIC Gb, Extb IIIC, Db Aromoured Cables ATEX & IECEx Cable Gland.

Hawke 501/453/RAC cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.

Flameproof AExd IIC Gb,

Increased Safety AExe IIC Gb

Dust AExtD Zone 21

Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

HAWKE 501/453/RAC CABLE GLAND TECHNICAL SPECIFICATION

Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, Extb IIIC Db

Certificate No’s  – Baseefa06ATEX0056X and IECEx BAS 06.0013X

Cable Gland Zone bbbbbbbb – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC

Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31

Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X

Deluge Protection – DTS01

Operating Temperature Range  -60°C to +100°C

CABLE GLAND SELECTION TABLE FOR HAWKE 501/453/RACHawke Size Ref.Entry Thread Size

Thread

Length

‘H’

Cable Acceptance Details‘G’ Compressed LengthHexagon DimensionsInner Sheath ‘A’Outer Sheath ‘B’‘C’ Armour/BraidStandard SealAlternative Seal (S)MetricNPT *StandardOptionMin.Max.Min.Max.Min.Max.

Orien

tation 1

Orien

tation 2

Across FlatsAcross CornersOsM20 ‡½”–153.08.0––5.512.00.8 / 1.250 / 0.852.024.026.5OM20 ‡½”–156.511.9––9.516.00.8 / 1.250 / 0.852.024.026.5AM20¾”½”1510.014.39.013.412.520.50.8 / 1.250 / 0.853.030.032.5BM251″¾”1513.020.29.515.416.926.01.25 / 1.60 / 0.759.536.039.5CM321¼”1″1519.526.515.521.222.033.01.6 / 2.00 / 0.764.046.050.5C2M401½”1¼”1525.032.522.028.028.041.01.6 / 2.00 / 0.768.355.060.6DM502″1½”1531.544.4/42.3 †27.534.836.052.61.8 / 2.50 / 1.079.065.070.8EM632½”2″1542.556.3/54.3 †39.046.546.065.31.8 / 2.50 / 1.078.480.088.0FM753″2½”1554.568.2/65.3 †49.558.357.078.01.8 / 2.50 / 1.083.795.0104.0GM803½”–2067.073.0––75.089.52.0 / 3.50 / 1.095.6106.4115.0HM903½”–2067.077.6––75.089.52.0 / 3.50 / 1.095.6115.0130.0JM1004″–2077.091.6––88.0104.52.5 / 4.00 / 1.095.6127.0142.0

All dimensions in millimetres (except*).
Os – F size metric entry threads are 1.5mm pitch as standard. For G size Cable Glands and above, a 2mm pitch is supplied as standard (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering.
† Smaller value is applicable when selecting reduced NPT entry option.
Sizes Os and O are available with an M16 thread size. For O size with an M16 thread, the maximum cable inner sheath diameter is 10.9mm.

CABLE GLAND MATERIAL & FINISH

Hawke 501/453/RAC cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

PREPARING CABLE & GLAND FOR INSTALLING HAWKE 501/453/RAC

CABLE PREPARATION

Strip Cable to suit equipment as shown above and expose the armour/braid ‘I’.

‘I’ = 20mm for cable gland sizes Os to C ‘I’ = 25mm for cable gland sizes C2 to F ‘II’ = to suit equipment. If required, fit shroud.

CABLE GLAND PREPARATION

Push the cable through the armour spigot (4). Spread armour/braid over the armour spigot (4) until the end of the armour/braid is up against the shoulder of the armour cone. bbbbbbbb the armour clamping ring (3).

Remove the inner seal (5) from the entry (6). Place the entry (6) over the armour spigot (4). Move the sub-assembly (1) and (2) up to meet the entry (6). Note: If the equipment has a threaded entry, it may be advisable to screw the entry component into the equipment to prevent twisting of the cable after step D

Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.

501/421 Cable Gland Unarmoured   – outer cable sheath cable sealing

501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath

501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas

ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

Hawke防爆格兰(Hawke Cable Glands-上海颐品自动化)

Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

Hawke防爆格兰代理商:上海颐品自动化科技有限公司(4008552521)

关键词:Hawke防爆格兰,Hawke防爆变径,Hawke防爆堵头,Hawke防爆呼吸阀,Hawke防爆接线盒,Hawke防爆控制箱

Hawke防爆格兰等产品规格书及相关资料-请咨询上海颐品自动化科技有限公司



联系方式
返回展厅